iVep9 Vaporizer
High precision anesthetic vaporizer with imported materials, perfectly reflecting pressure, flow and temperature compensation, providing accurate output consistent with the dial setting during surgery, greatly satisfying anesthetic demand with low flow 50ml-15L and free of maintenance during lifetime.
Various application range
Free of maintenance during lifetime with superb performance is over a wide range of vapour concentration and temperatures, particularly at low flows
Support Agents: Halothane, Enflurane, Isoflurane, Sevoflurane
Anesthetic Filling Way: Keyed Filler, Quick Fil, or Pour Fill
Liquid anesthetic remainder indication, Convenient to check anesthetic in the standard range
Interlock switch, more safety during using more than two Vaporizers
More filling way, quick Fil can work in enclosed condition, no leakage or evaporation, safe in the operation room.
Economy Meets Ergonomics
Ivep9 vaporizers have been designed to accommodate 300ml of liquid anesthetic.
That is more than the entire volume of a standard bottle. You can even add 250ml if the vapor is not quite empty. This means you can easily refill a Vapor and have it back in service quickly without having to worry about where to store the remainder of the anesthetic you are using.
Highly Compatible
Ivep9 vaporizers were designed to work with practically any VetCare anesthesia machine or workstation, and suitable for other anesthesia with standard 23mm ISO connector.
Made with Patient Safety in Mind
The color of each vaporizer corresponds of the color code of the anesthetic agent for which it was designed. The shape of each filling nozzle prevents filling the vaporizer with the wrong anesthetic agent. Ivep9 comfort mounting also effectively eliminates the possibility of activating more than one vaporizer at a time.Once one vaporizer is turned on, the other is automatically blocked. Taken together, these features result in enhanced patient safety and a reduced likelihood of significant user error.
Technical Specification:
Concentration:
Halothane 0.2 to 6%,
Enflurance 0.2 to 8%,
Isoflurance 0.2 to 6%,
Sevoflurane 0.2 to 8%
Temperature Range:
Ambient and Vapor temperature
during operation: 10 to 40°C
during shut-down(filled, control dial at OFF): O to 40°C
during storage(empty,dry wick): -20 to 70°C
Flow Range:
0.05 to 15 L/min
0.05 to 10L/min for concentration>5 vol.%
Filling Volume for Anesthetic Agent:
about 360ml with dry wick about 300ml with moist wick
about 260 ml between minimum and maximum mark
Maximum Angle of Tilt:
During transport(control dial at “OFF”) any position and angle
During operation 30°